TRF016—2010 Dongguan New Shengda Lighting Co.,Ltd. (东进照明有限公司) Test Report (测试报告) Glow-wire test (灼热丝试验) Appliance (产品名称): Sample description (样品描述): ERP No. or new sample (物料编码或新测试样品): Photos of sample (样品照片) Supplier.(供应商): Date (日期): Quantity of test samples (测试的样品数量): Test mothod (测试标准): Clause 13.3.2 of IEC 60598-1:2008 or IEC 60695-2-10 □ Before conducting glow-wire test, specimen is placed in the flammability test room for at least 24 h in atmosphere having a temperature b/w 15ºC and 35ºC and a relative humidity b/w 45% and 75%! (操作灼热丝试验之前,测试样品应在环境温度15 ºC到35 ºC,湿度45%到75%的易燃测试房间内放置24h) □ Calibration status of equipment checked (仪器计量证书检查) □ Pull force for carriage measured, 1 N +0.2N (砝码拉力1 N +0.2N) □ Clear handwriting! (清晰的字迹) □ Clean glow wire tip before EVERY test ! (每次测试清洁灼热丝颈部) GLOW-WIRE TEST (灼热丝测试) ( Pass condition: 1. duration of burning after 30s shall not exceed 30s. 2. drops not ignite the paper) 合格条件:1, 30s灼热时间后,样品持续燃烧时间不超过30s。 2, 滴落物不引燃薄棉纸) No. 编号 Test material 测试的材料 Current(A) Temp. [°C] 负载电流 测试温度 te (s) 持燃时间 Observation 观察现象 Result 结果 □Flame (有明火) □No flame (无明火) □650°C 1 □750°C □850°C □Drops (有滴落物) □No drops (无滴落物) □Drops ignite the paper (滴落物引燃棉纸) □Drops scorch pinewood (滴落物烧焦木板) □Drops didn’t ignite the paper and scorch pinewood (滴落物没有引燃棉纸和烧焦木板) □Pass(合格) □Fail (不合格) 2 □650°C □750°C □850°C □Flame (有明火) □No flame (无明火) □Drops (有滴落物) □No drops (无滴落物) □Drops ignited the paper (滴落物引燃棉纸) □Pass(合格) □Drops scorched pinewood(滴落物烧焦木板) □Fail (不合格) □Drops didn’t ignite the paper and scorch pinewood (滴落物没有引燃棉纸和烧焦木板) Remark (备注): Tested by (测试人): Checked by (审核人): Approved by(批准): Edited by(编制):
Test report No.: